Perfectly suits for the supply of sensors, measuring devices, regulators, registering devices, PLCs and other elements of industrial automation systems of the economic and household purposes.

Conversion of supply voltage into a stabilized D.C.output voltage.

  • Operation within a wide temperature range from -40 to +55 °С;
  • Overload, short circuit and overheating protection;
  • Power supply filter reducing the disturbance level;
  • “Soft start” system with stater current limitation;
  • Indication of the voltage on the unit outputs;
  • Possibility to regulate the output voltage within the range ±10 %;

It is possible to connect several units БПИ-125 in a parallel and consecutive way without additional external protection devices and output current equalization.

Manufactured in accordance with the technical conditions EI.97.00.000 TC

Использование Functional equipment

The unit is single-channel, the output channel is galvanically separated from the input supply voltage.

The unit includes a built-in “soft start” circuit with starting current limitation, a power supply filter reducing the disturbance level down to the necessary limits in the supply net and preventing the supply net disturbances from passing, a line-side fuse activated in case of internal defects in the unit.

The unit is protected from short circuit (KZ) and overload activated at the increase of output current up to 130% of Iном providing for an automatic restoration at overload elimination. The unit БПИ-24 implements the function of output power limitation at the current exceeding 120% Iном.

At the heating of a unit key cascade to 125 °C the heat protection is tripped. The unit is automatically switched on at the cascade cooling down to 70 °C. The units БПИ-24, БПИ-30, БПИ-60, БПИ-125 are naturally cooled. The unit БПИ-250 has a fan with an automatic start at the unit heating up to more than 60 °С.

Key technical characteristics

ParameterValue
A.C. supply voltage range, V 184...264* (БПИ-30, БПИ-60, БПИ-125, БПИ-250)

100…265 (БПИ-24)
D.C. supply voltage range, V 250...370
A.C. supply voltage frequency, Hz 45...65
Number of channels 1
Output voltage instability 0,2 (БПИ-30, БПИ-60)
0,5 (БПИ-24, БПИ-125, БПИ-250)
Output voltage temperature drift, %, for every 10 °C not more than ±0.2
Output voltage pulsation (peak-peak), % not more than 0,7
Insulation strength between the input supply channel and output channel, V 1500
Time of operating mode setting, sec not more than 1
Structural design plastic body frame with a DIN or wall mounting option (БПИ-24, БПИ-30, БПИ-60)

metal body frame with a DIN mounting option (БПИ-125, БПИ-250)

* — by the customer’s order it is possible to manufacture the unit with the A.C. supply voltage range 95...132 V or by 130...190 V DC mains.

The power supply unit can regulate output voltage. The output voltage regulating range is ±10 %, i.e., the change range is 20 %. The units have a dependence between extreme points of the output voltage adjustment range and output power at which the protection is tripped. If at the maximum output voltage the unit demonstrates a data sheet power, at the minimum output voltage the current protection could switch off the source providing a lower output current comparing to the data sheet value. It is necessary to take into account when choosing a power supply unit and maximum load calculation.

The unit circuit (except for БПИ-24) includes a relay (connector XT2) for the alarm at output voltage presence/absence (1A, 250 V).

Options of versions depending on output voltages and currents

Output power, WConsumed power, V·АOutput voltage, VMaximum channel load current, APerformance factor more than, %Weight, kg, not more
24 29 12 2,00 79 0,20
24 1,00 82
36 0,65 82
48 0,50 82
30 37 12 2,50 79 0,20
36 24 1,25 81
37 36 0,85 78
37 48 0,65 78
60 73 12 5,00 79 0,45
71 24 2,50 83
71 36 1,50 82
72 48 1,25 80
125 153 12 10,00 78 1,00
145 24 5,00 84
147 36 3,50 83
144 48 2,50 85
250 288 12 20,00 85 1,40
278 24 10,00 89
280 36 7,00 88
275 48 5,00 90

БПИ-24 - external appearance

Appearance БПИ-24

1 — terminal blocks DG128-5.0-02P to connect output voltage;
2 — LED indicating output voltage:
     — light on — voltage on the unit output is normal;
     — light off — defect, short circuit or overload of a channel;
3 — resistor to regulate output voltage in the range ± 10 %;
4 — terminal boxes DG128-5.0-03P to connect supply voltage;
5 — warranty label;
6 — DIN-rail.

БПИ-30 - внешний вид

Appearance БПИ-30

 

БПИ-60 - внешний вид

Appearance БПИ-60

БПИ-125 -внешний вид

Appearance БПИ-125

1 — terminal blocks DG25R-B-04P to connect output voltage;
2 — connector 2EDGK-5.0-03P to connect relay contacts;
3 — LED indicating output voltage:
       — light on — voltage on the unit output is normal;
       — light off — defect, short circuit or overload of a channel;
4 — resistor to regulate output voltage in the range ± 10 %;
5 — terminal boxes 2EDGK-5.0-03P to connect supply voltage;
6 — warranty label;
7 — DIN-rail.

БПИ-250 - внешний вид

Appearance БПИ-250 

Electric connection diagram БПИ-24

Electric connection diagram БПИ-24

Electric connection diagram БПИ-30

Electric connection diagram БПИ-30

Electric connection diagram БПИ-60

Electric connection diagram БПИ-60

Electric connection diagram БПИ-125, БПИ-250

Electric connection diagram БПИ-125, БПИ-250

 

ParameterValue
Ambient temperature, °С -10...+55*
In terms of climatic effect resistance at operation corresponds to the version group, under GOST R 52931–2008 С3
In terms of mechanical impact resistance at operation corresponds to the version group, under GOST R 52931–2008 L3
Ingress protection level, under GOST 14254–96 IP20

* — by the customer’s order it is possible to manufacture a version with a temperature range−40...+55 °С (except for БПИ-250).

Warranty liabilities

ParameterValue
Warranty operating life, months 36 months since the commissioning date but no more than 42 months since the date of manufacture

Contents of delivery

NameDesignationNumberNote
БПИ   1  
Data sheet, Operation manual   1  
Terminal board (3 contacts) 2EDGK-5.0-03P 2 для БПИ-125, БПИ-250
DIN rail NS35\7,5 м by order

Designations at the order

БПИ250241040360
1 2 3 4 5 6
  1. Name.
  2. Output power, W.
  3. Output voltage, V.
  4. Load current, A.
  5. Temperature range:
    • 10 — temperature range −10...+55 °C;
    • 40 — temperature range −40...+55 °C.
  6. Additional technological no-failure operating time 360 hours.

 

PositionTemperature rangeCost, VAT exclusive, rub.
БПИ-24 from –10°С 1740
от –40°С 2175
БПИ-30 from –10°С 1830
from –40°С 2287
БПИ-60 from –10°С 2210
from –40°С 2762
БПИ-125 from –10°С 4370
from –40°С 4807
БПИ-250 from –10°С 5700

Impulse power supply units БПИ