Membrane phase separators with an open membrane РСМ-306

1000 characters left
Обработка персональных данных включает согласие с Пользовательским соглашением и Политикой конфиденциальности и Вы принимаете их условия.

Phase separators are intended for the protection of sensitive elements of measuring devices (manometers, vacuum meters, vacuum pressure gauges, pressure gauges) from the direct contact with corrosion-active crystalized liquid and gaseous media as well as with high-viscosity media.

Manufactured in accordance to TC 4212-001-59541470-2008

Использование Pressure

Key technical characteristics

Parameter Value
РСМ-306-Dу50 РСМ-306-Dу80
Nominal diameter Dу 50 80
Nominal pressure Ру, MPa 0,6; 1,6; 2,5; 4,0; 10 under GOST 12815
Connection dimensions at the medium input ГОСТ 12815 ver.2 (Range 2)
Operating temperature range, °С depends on the separating liquid type and sealing material
Maximum displaceable chamber volume, cm3 0,55 2,2
Internal volume filled with a separating liquid, cm3 2,0 3,5
Flange material Ст20 (at t down to −25, оС)
at the order 09Г2С (at t up to −40, оС)

 

РСМ-306 - габаритные и присоединительные размеры

Dу Ру, MPa D, mm H, mm Dw, mm d0, mm n, pc. d, mm h, mm Weight, kg, not more
50 0,63 140 50 110 14 4 80 28 2,8
1,6 160 50 125 18 87 28 3,7
2,5 160 50 125 18 28 3,7
4,0 160 55 135 18 33 4,0
6,3 175 60 145 22 39 5,6
10,0 195 73 150 26 52 8,9
80 0,63 185 50 150 18 4 115 25 4,6
1,6 195 55 160 18 120 33 6,3
2,5 195 55 160 18 8 33 6,1
4,0 195 62 160 18 40 6,7
6,3 210 68 170 22 46 8,8
10,0 230 82 180 26 60 13,1

Materials contacting with operating media

membrane body frame parts gasket
Alloy 36НХТЮ Steel 12Х18Н10Т Copper

Warranty liabilities

Parameter Value
Warranty operating life, months 36 months since the commissioning date but no more than 42 months since the date of manufacture

Contents of delivery

Name Number
Phase separator 1
Copper packing 1
Data Sheet 1
Spare part kit by order

Designations at the order

РСМ-306 Dу50 Pу2,5 М20×1,5 Ст20
1 2 3 4 5
  1. Name.
  2. Nominal diameter Dy (tab "Dimensions and sizes").
  3. Nominal pressure under GOST 12815 P(tab “Dimensions and sizes").
  4. Connection size of thread under a measurement device (М20х1,5 or G1/2).
  5. Flange material (as per the table "Key Technical Characteristics").

By the special order, a phase separator is supplied in a kit with a measuring device, capillary line as well as with a vacuum liquid filling: ПМС-5, ПЭФ-70/110, ПФМС-4.

Membrane phase separators with an open membrane РСМ-306

Membrane phase separators with an open membrane РСМ-306
wait Item successfully added.
Proceed to checkout?
1000 characters left
Обработка персональных данных включает согласие с Пользовательским соглашением и Политикой конфиденциальности и Вы принимаете их условия.